PANASONIC T-CAP ALL-IN-ONE 9 kW KIT AXC9HE8 heat pump


  • Product Description
  • Product Features
  • Add to the product comparison toolCompare
Added to the product comparison tool
You may add 2 to 4 products
You may add 4 products maximum
Go to Comparison Tool

Product Description

PANASONIC T-CAP ALL-IN-ONE 9 kW KIT AXC9HE8 heat pump

 

Kit

KIT-AXC09HE8

Heating capacity (A +7°C, W 35°C)

kW

9,00

COP (A +7°C, W 35°C)

4,84

Heating capacity (A +7°C, W 55°C)

kW

9,00

COP (A +7°C, W 55°C)

2,94

Heating capacity (A +2°C, W 35°C)

kW

9,00

COP (A +2°C, W 35°C)

3,59

Heating capacity (A +2°C, W 55°C)

kW

9,00

COP (A +2°C, W 55°C)

2,21

Heating capacity (A -7°C, W 35°C)

kW

9,00

COP (A -7°C, W 35°C)

2,85

Heating capacity (A -7°C, W 55°C)

kW

9,00

COP (A -7°C, W 55°C)

2,02

Cooling capacity (A 35°C, W 7°C)

kW

7,00

EER (A 35°C, W 7°C)

3,17

Cooling capacity (A 35°C, W 18°C)

kW

7,00

EER (A 35°C, W 18°C)

5,19

Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C)

ηs %

181 / 130

Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C)

SCOP

4,60 / 3,33

Heating average climate. Energy class (W 35°C / W 55°C) (1)

A+++ to D

A+++ / A++

Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C)

ηs %

235 / 158

Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C)

SCOP

5,95 / 4,03

Heating warm climate. Energy class (W 35°C / W 55°C) (1)

A+++ to D

A+++ / A+++

Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C)

ηs %

160 / 125

Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C)

SCOP

4,08 / 3,20

Heating cold climate. Energy class (W 35°C / W 55°C) (1)

A+++ to D

A++ / A++

Indoor unit

WH-ADC0916H9E8

Indoor sound pressure (Heat)

dB(A)

33

Indoor sound pressure (Cool)

dB(A)

33

Indoor dimension (Height)

mm

1800

Indoor dimension (Width)

mm

598

Indoor dimension (Depth)

mm

717

Indoor net weight

kg

126

Water pipe connector

Inch

R 1¼

A class pump (Number of speeds)

Variable Speed

A class pump (Input power Min)

W

36

A class pump (Input power Max)

W

152

Heating water flow (∆T=5 K. 35°C)

L/min

25,80

Capacity of integrated electric heater

kW

9,00

Indoor recommended fuse

A

16 / 16

Recommended cable size, supply 1

mm²

5 x 1,5

Recommended cable size, supply 2

mm²

5 x 1,5

Water volume

L

185

Maximum water temperature

°C

65

Material inside tank

Stainless steel

Tapping profile according EN16147

L

DHW tank ERP average climate efficiency rating (2)

A+ to F

A

DHW tank ERP warm climate efficiency rating (2)

A+ to F

A

DHW tank ERP cold climate efficiency rating (2)

A+ to F

A

DHW tank ERP average climate η

ηwh %

95

DHW tank ERP average climate SCOP

2,38

DHW tank ERP warm climate η

ηwh %

110

DHW tank ERP warm climate SCOP

2,75

DHW tank ERP cold climate η

ηwh %

75

DHW tank ERP cold climate SCOP

1,88

Outdoor unit

WH-UX09HE8

Outdoor sound power part load (Heat) (3)

dB(A)

65

Outdoor sound power full load (Heat)

dB(A)

68

Outdoor sound power full load (Cool)

dB(A)

67

Outdoor dimension (Height)

mm

1340

Outdoor dimension (Width)

mm

900

Outdoor dimension (Depth)

mm

320

Outdoor net weight

kg

108

Refrigerant (R410A) / CO2 Eq.

kg / T

2,85 / 5,951

Pipe diameter (Liquid)

Inch (mm)

3/8 (9,52)

Pipe diameter (Gas)

Inch (mm)

5/8 (15,88)

Pipe length range

m

3 ~ 30

Elevation difference (in/out)

m

20

Pipe length for additional gas

m

10

Additional gas amount

g/m

50

Operation range (Outdoor ambient)

°C

-28 ~ +35

Water outlet (Heat)

°C

20 ~ 60

Water outlet (Cool)

°C

5 ~ 20

 

Product Features