PANASONIC T-CAP 9 kW 230V KIT WXC09H3E8 heat pump

 

 

9 kW

Kit

KIT-WXC09H3E8

Heating capacity (A +7°C, W 35°C)

kW

9,00

COP (A +7°C, W 35°C)

4,84

Heating capacity (A +7°C, W 55°C)

kW

9,00

COP (A +7°C, W 55°C)

2,94

Heating capacity (A +2°C, W 35°C)

kW

9,00

COP (A +2°C, W 35°C)

3,59

Heating capacity (A +2°C, W 55°C)

kW

9,00

COP (A +2°C, W 55°C)

2,21

Heating capacity (A -7°C, W 35°C)

kW

9,00

COP (A -7°C, W 35°C)

2,85

Heating capacity (A -7°C, W 55°C)

kW

9,00

COP (A -7°C, W 55°C)

2,02

Cooling capacity (A 35°C, W 7°C)

kW

7,00

EER (A 35°C, W 7°C)

3,17

Cooling capacity (A 35°C, W 18°C)

kW

7,00

EER (A 35°C, W 18°C)

5,19

Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C)

ηs %

181 / 130

Heating average climate. Seasonal energy efficiency (W 35°C / W 55°C)

SCOP

4,60 / 3,33

Heating average climate. Energy class (W 35°C / W 55°C) (1)

A+++ to D

A+++ / A++

Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C)

ηs %

235 / 158

Heating warm climate. Seasonal energy efficiency (W 35°C / W 55°C)

SCOP

5,95 / 4,03

Heating warm climate. Energy class (W 35°C / W 55°C) (1)

A+++ to D

A+++ / A+++

Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C)

ηs %

160 / 125

Heating cold climate. Seasonal energy efficiency (W 35°C / W 55°C)

SCOP

4,08 / 3,20

Heating cold climate. Energy class (W 35°C / W 55°C) (1)

A+++ to D

A++ / A++

Indoor unit

WH-SXC09H3E8

Indoor sound pressure (Heat)

dB(A)

33

Indoor sound pressure (Cool)

dB(A)

33

Indoor dimension (Height)

mm

892

Indoor dimension (Width)

mm

500

Indoor dimension (Depth)

mm

340

Indoor net weight

kg

43

Water pipe connector

Inch

R 1¼

A class pump (Number of speeds)

Variable Speed

A class pump (Input power Min)

W

32

A class pump (Input power Max)

W

102

Heating water flow (∆T=5 K. 35°C)

L/min

25,80

Capacity of integrated electric heater

kW

3,00

Indoor recommended fuse

A

16 / 16

Recommended cable size, supply 1

mm²

5 x 1,5

Recommended cable size, supply 2

mm²

3 x 1,5

Outdoor unit

WH-UX09HE8

Outdoor sound power part load (Heat) (3)

dB(A)

65

Outdoor sound power full load (Heat)

dB(A)

68

Outdoor sound power full load (Cool)

dB(A)

67

Outdoor dimension (Height)

mm

1340

Outdoor dimension (Width)

mm

900

Outdoor dimension (Depth)

mm

320

Outdoor net weight

kg

108

Refrigerant (R410A) / CO2 Eq.

kg / T

2,85 / 5,951

Pipe diameter (Liquid)

Inch (mm)

3/8 (9,52)

Pipe diameter (Gas)

Inch (mm)

5/8 (15,88)

Pipe length range

m

3 ~ 30

Elevation difference (in/out)

m

30

Pipe length for additional gas

m

10

Additional gas amount

g/m

50

Operation range (Outdoor ambient)

°C

-28 ~ +35

Water outlet (Heat)

°C

20 ~ 60

Water outlet (Cool)

°C

5 ~ 20

 